220kV TERTIA PERIODO DE-ONUS VOLTAGE ORDINATIONE
TRANSFORMATOR
Summarium
220kV Oleum tres phase immersum in-onus intentionis regulantis transformator efficit seriem mutationum maioris in terminis materialibus, technicis, et constructionibus.Proprium est constructionis compactae;
Maximum pondus, altum efficientiam, humilis damnum, humilis strepitus, et perficientur firmitas.Productum potest reducere magna damna in egetis et in expensis operandis et extendere efficaciam oeconomicam distinctam.
Productum sequitur signa nationalia: GB1094.1-2013 Transformatores Potentiae Pars I: Generalis;GB1094.2-2013
Virtus Transformatores Pars II: Temperatura oritur;GB1094.3-2003 Potentia Transformatores Pars 3: Insulation campester, dielectric probationes et alvi externas in aere;GB1094.5-2003 Virtutis Transformatores Pars V: Facultas breve spatium sustinendi;
GB/T6451-2015 Specificationis et technicae requisita per tres periodos oleum potentiae transformatores immergunt.
Praecipua 220kV gradus tres phase on-onus voltage regulantis potentiae transformer technicae parametri | ||||||||
Ratum capacitas (kVA) | Voltage Compositum | Vector Gourp | Nullus onus Damnum | Load Loss | Non Load Current | Brevis circuitus Impedimentum % | ||
HV (kV) | LV k(V) | kW | kW | % | ||||
31500 | 6.3 6.6 10.5 11 | YNd11 | 28 | 128 | 0.56 | 12-14 | ||
40000 | 32 | 149 | 0.56 | |||||
50000 | 39 | 179 | 0.52 | |||||
63000 | 46 | 209 | 0.52 | |||||
75000 | 10.5 13.8 | 53 | 237 | 0.48 | ||||
90000 | 64 | 273 | 0.44 | |||||
120000 | 75 | 338 | 0.44 | |||||
150000 | 220±2*2.5% | 10.5,11,13.8 | 89 | 400 | 0.40 | |||
160000 | 242±2*2.5% | 15.75 | 93 | 420 | 0.39 | |||
180000 | 18,20 | 102 | 459 | 0.36 | ||||
240000 | 128 | 538 | 0.33 | |||||
300000 | 13.8 15.75 18 21 | 154 | 641 | 0.30 | ||||
360000 | 17 | 735 | 0.30 | |||||
370000 | 176 | 750 | 0.30 | |||||
400000 | 187 | 795 | 0.28 | |||||
420000 | 193 | 824 | 0.28 |
Nota 1 Transformatores cum facultate aestimata minus quam 31500 kVA et aliae compositiones voltagenae possunt etiam secundum exigentiam praeberi.
Nota 2 Transformatores submissa intentione 35 kV vel 38.5 kV etiam exigente provideri possunt.
Nota 3 In non-discissione structurae praeponitur.Si aliqua postulatio operandi sit, sub-connexiones erigi possunt.
Nota 4. Quando medium onus annuum commutatoris est inter 45% et 50%, maximum efficientiae operativae obtineri potest utendo valorem iacturae in mensa.
31500-300000kVA tres tempus tres -winding non-agrum excitatio mutans potestatem transformer | ||||||||||
Ratum capacitas (kVA) | Voltage Compositum | Vector Group | Nullus onus damnum kW | Load damnum kW | Non onus current % | Brevis circuitus impedimentum (% | ||||
Aluminium kV | Med-ium Voltage (kV) | Humilis Voltage (kV) | Descenderet reclamantibus | Descenderet reclamantibus | ||||||
31500 | 6.3,6.6 10.5,21 36,37 38.5 | 32 | 153.00 | 0.56 | ||||||
40000 | 38 | 183.00 | 0.5 | |||||||
50000 | 44 | 216.00 | 0.44 | |||||||
63000 | 52 | 257.00 | 0.44 | HM | HM | |||||
90000 | 220±2*2.5% | 69 | 10.5,13.8 21,36,37 38.5 | YNyn0d11 | 68 | 333.00 | 0.39 | 22-24 | 22-24 | |
120000 | 230±2*2.5% | 115 | 84 | 410 | 0.39 | HL | HL | |||
150000 | 242±2*2.5% | 121 | 100 | 487 | 0.33 | 12-14 | 12-14 | |||
180000 | 10.5,13.8 15.75,21 37,38.5 | 113 | 555 | 0.33 | ML | ML | ||||
240000 | 140 | 684 | 0.28 | 7-9 | 7-9 | |||||
300000 | 166 | 807 | 0.24 |
Nota 1: Facultas destinatio oneris iacturae in mensa est (100/100/100)%.Facultas destinatio boost structuram esse potest
(100/50/100)%.Facultas destinatio structurae Buck esse potest (100/50/100)% vel (100/50/100)%.
Nota 2: Transformatores cum capacitate aestimata minus quam 31500 KA, et aliae compositiones voltagenae possunt etiam secundum exigentiam praeberi.
Nota 3: Transformatores humili intentione 35 kV provideri etiam possunt ut requiritur.
Nota 4: prioritas ad structuram non scissuram danda est.Si operatio requirit, rumpendi possunt.
Nota 5: Cum mediocris annui oneris commutator est inter 45%, maximum efficientia operativa obtineri potest utendo valore in mensa iactura.
31500kVA-180000kVA three-phase duplex sinuosa on-onus ICTUS mutans potestatem TRANSFIGURATOR | |||||||||
Ratum capacitas (kVA) | Voltage Compositum | Vector Gourp | Nullus onus Damnum | Load Loss | Non Load Current | Brevis circuitus Impedimentum % | |||
HV (kV) | LV k(V) | kW | kW | % | |||||
31500 | 6.3,6.6 10.5,11,21 36,37 38.5 | 30 | 128 | 0.57 | 12-14 | ||||
40000 | 36 | 149 | 0.57 | ||||||
50000 | 43 | 179 | 0.53 | ||||||
63000 | 50 | 209 | 0.53 | ||||||
90000 | 64 | 273 | 0.45 | ||||||
120000 | 220±8*1.25% | 10.5,11,21 36,37 38.5 | YNd11 | 79 | 338 | 0.45 | |||
150000 | 230±8*2.5% | 92 | 400 | 0.41 | |||||
180000 | 108 | 459 | 0.38 | ||||||
120000 | 81 | 337 | 0.45 | ||||||
150000 | 66 69 | 96 | 394 | 0.41 | |||||
180000 | 112 | 451 | 0.38 | ||||||
240000 | 140 | 560 | 0.30 |
31500kVA-240000kVA three-phase three-flexing on-onus ICTUS mutabilis potentia TRANSFIGURATOR | |||||||||
Ratum capacitas (kVA) | Voltage Compositum | Nullus onus Damnum | Load Loss | Non Load Current | Vector group | Brevis circuitus Impedimentum % | capacitas adsignatio | ||
HV (kV) | Med-ium Voltage (kV) | LV k(V) | kW | kW | % | ||||
31500 | 6.3 6.6 10.5 11 21 33 36 37 38.5 | 35 | 153.00 | 0.63 | HM 12-14 HL 22-24 ML 7-9 | 100/100/100 100/50/100 100/100/50 | |||
40000 | 41 | 183.00 | 0.60 | ||||||
50000 | 48 | 216.00 | 0.60 | ||||||
63000 | 69 | 56 | 257.00 | 0.55 | |||||
90000 | 220±8*1.25% | 115 | 10.5 11 21 33 36 37 38.5 | 73 | 333.00 | 0.44 | YNyn0d11 | ||
120000 | 230±8*1.25% | 121 | 92 | 410 | 0.44 | ||||
150000 | 108 | 487 | 0.39 | ||||||
180000 | 124 | 598 | 0.39 | ||||||
240000 | 154 | 741 | 0.35 |
Nota 1The notitiae in tabula inscriptae applicandae sunt ad productorum structurarum depressurizatorum, et productorum structurarum boost etiam exigente provideri possunt.
Nota 2 Transformatores submissa intentione 35 kV etiam ut postulabat praeberi possunt.
Nota 3 Cum mediocris annui oneris commutator est inter 45% et 50%, maximum efficientiae operativae obtineri potest utendo valorem iacturae in mensa.
31500kVA-240000kVA three-phase three-flexer on-onus auto-iuncta potestas TRANSFIGURATOR | |||||||||
Ratum capacitas (kVA) | Voltage Compositum | Nullus onus Damnum | Load Loss | Non Load Current | Vector group | Brevis circuitus Impedimentum % | capacitas adsignatio | ||
HV (kV) | Med-ium Voltage (kV) | LV (kV) | kW | kW | % | ||||
31500 | 6.3 6.6 10.5 21 36 37 38.5 | 20.0 | 102 | 0.44 | YNyn0d11 | HM 8-11 HL 28-34 ML 18-24 | 100/100/50 | ||
40000 | 24.0 | 125 | 0.44 | ||||||
50000 | 28.0 | 149 | 0.39 | ||||||
63000 | 33.0 | 179 | 0.39 | ||||||
90000 | 220±8*1.25% | 115 | 40.0 | 234 | 0.33 | ||||
120000 | 230±8*1.25% | 121 | 10.5 21 36 37 38.5 | 51.0 | 292 | 0.33 | |||
150000 | 60.0 | 346 | 0.28 | ||||||
180000 | 68.0 | 398 | 0.28 | ||||||
240000 | 83.0 | 513 | 0.24 |
Nota 1 Notitia quae in tabula inscripta sunt, producta structurarum depressurizatorum applicanda sunt, et productorum structurarum boost etiam exigente provideri possunt.
Nota 2 Transformatores cum intentione humili 35 kV etiam ut requiritur provideri possunt.
Nota 3 Cum mediocris annui oneris commutator est inter 45% et 50%, maximum efficientiae operativae obtineri potest utendo valorem iacturae in mensa.
31500kVA-240000kVA three-phase three-flexer on-onus auto-iuncta potestas TRANSFIGURATOR | |||||||||
Ratum capacitas (kVA) | Voltage Compositum | Nullus onus Damnum | Load Loss | Non Load Current | Vector group | Brevis circuitus Impedimentum % | capacitas adsignatio | ||
HV (kV) | Med-ium Voltage (kV) | LV (kV) | kW | kW | % | ||||
31500 | 6.3 6.6 10.5 21 36 37 38.5 | 20.0 | 102 | 0.44 | YNyn0d11 | HM 8-11 HL 28-34 ML 18-24 | 100/100/50 | ||
40000 | 24.0 | 125 | 0.44 | ||||||
50000 | 28.0 | 149 | 0.39 | ||||||
63000 | 33.0 | 179 | 0.39 | ||||||
90000 | 220±8*1.25% | 115 | 40.0 | 234 | 0.33 | ||||
120000 | 230±8*1.25% | 121 | 10.5 21 36 37 38.5 | 51.0 | 292 | 0.33 | |||
150000 | 60.0 | 346 | 0.28 | ||||||
180000 | 68.0 | 398 | 0.28 | ||||||
240000 | 83.0 | 513 | 0.24 |
1.Products exclusive in indice producti etiam in usuario requisita praeberi possunt. Performance productorum amet.
2. Medium voltage fabrica potest eligere valorem voltage aut sonum praeter ea quae in mensa super usoris exigentia nominantur. Summus intentione percussus eligere potest percussionem asymmetricam regulantem.
3. Brevis impedimentum ambitus alium pretii eligere potest quam ea quae in tabula definita sunt.
4.Final size is based on drawings of signed contract.