220kV genus trium tempus in-onus

  • Product Details
  • FAQ
  • Download

220kV TERTIA PERIODO DE-ONUS VOLTAGE ORDINATIONE

TRANSFORMATOR

Summarium

220kV Oleum tres phase immersum in-onus intentionis regulantis transformator efficit seriem mutationum maioris in terminis materialibus, technicis, et constructionibus.Proprium est constructionis compactae;
Maximum pondus, altum efficientiam, humilis damnum, humilis strepitus, et perficientur firmitas.Productum potest reducere magna damna in egetis et in expensis operandis et extendere efficaciam oeconomicam distinctam.
Productum sequitur signa nationalia: GB1094.1-2013 Transformatores Potentiae Pars I: Generalis;GB1094.2-2013
Virtus Transformatores Pars II: Temperatura oritur;GB1094.3-2003 Potentia Transformatores Pars 3: Insulation campester, dielectric probationes et alvi externas in aere;GB1094.5-2003 Virtutis Transformatores Pars V: Facultas breve spatium sustinendi;
GB/T6451-2015 Specificationis et technicae requisita per tres periodos oleum potentiae transformatores immergunt.

1

Praecipua 220kV gradus tres phase on-onus voltage regulantis potentiae transformer technicae parametri
Ratum
capacitas
(kVA)
Voltage Compositum Vector Gourp Nullus onus Damnum Load Loss Non Load
Current
  Brevis circuitus
Impedimentum
%
HV
(kV)
LV
k(V)
kW kW %  
31500   6.3
6.6
10.5
11
YNd11 28 128 0.56   12-14
40000   32 149 0.56  
50000   39 179 0.52  
63000   46 209 0.52  
75000   10.5
13.8
53 237 0.48  
90000   64 273 0.44  
120000   75 338 0.44  
150000 220±2*2.5% 10.5,11,13.8 89 400 0.40  
160000 242±2*2.5% 15.75 93 420 0.39  
180000   18,20 102 459 0.36  
240000     128 538 0.33  
300000   13.8
15.75
18
21
154 641 0.30  
360000   17 735 0.30  
370000   176 750 0.30  
400000   187 795 0.28  
420000   193 824 0.28  

Nota 1 Transformatores cum facultate aestimata minus quam 31500 kVA et aliae compositiones voltagenae possunt etiam secundum exigentiam praeberi.
Nota 2 Transformatores submissa intentione 35 kV vel 38.5 kV etiam exigente provideri possunt.
Nota 3 In non-discissione structurae praeponitur.Si aliqua postulatio operandi sit, sub-connexiones erigi possunt.
Nota 4. Quando medium onus annuum commutatoris est inter 45% et 50%, maximum efficientiae operativae obtineri potest utendo valorem iacturae in mensa.

 

31500-300000kVA tres tempus tres -winding non-agrum excitatio mutans potestatem transformer  
Ratum
capacitas
(kVA)
Voltage Compositum Vector Group Nullus onus damnum
kW
Load damnum
kW
  Non onus current
%
Brevis circuitus impedimentum (%
Aluminium
kV
Med-ium Voltage
(kV)
Humilis Voltage
(kV)
  Descenderet reclamantibus Descenderet reclamantibus
31500     6.3,6.6
10.5,21
36,37
38.5
  32 153.00   0.56    
40000       38 183.00   0.5    
50000       44 216.00   0.44    
63000       52 257.00   0.44 HM HM
90000 220±2*2.5% 69 10.5,13.8
21,36,37
38.5
YNyn0d11 68 333.00   0.39 22-24 22-24
120000 230±2*2.5% 115   84 410   0.39 HL HL
150000 242±2*2.5% 121   100 487   0.33 12-14 12-14
180000     10.5,13.8
15.75,21
37,38.5
  113 555   0.33 ML ML
240000       140 684   0.28 7-9 7-9
300000       166 807   0.24    

Nota 1: Facultas destinatio oneris iacturae in mensa est (100/100/100)%.Facultas destinatio boost structuram esse potest
(100/50/100)%.Facultas destinatio structurae Buck esse potest (100/50/100)% vel (100/50/100)%.
Nota 2: Transformatores cum capacitate aestimata minus quam 31500 KA, et aliae compositiones voltagenae possunt etiam secundum exigentiam praeberi.
Nota 3: Transformatores humili intentione 35 kV provideri etiam possunt ut requiritur.
Nota 4: prioritas ad structuram non scissuram danda est.Si operatio requirit, rumpendi possunt.
Nota 5: Cum mediocris annui oneris commutator est inter 45%, maximum efficientia operativa obtineri potest utendo valore in mensa iactura.

 

31500kVA-180000kVA three-phase duplex sinuosa on-onus ICTUS mutans potestatem TRANSFIGURATOR
Ratum
capacitas
(kVA)
Voltage Compositum Vector Gourp Nullus onus Damnum Load Loss Non Load
Current
  Brevis circuitus
Impedimentum
%
 
HV
(kV)
LV
k(V)
kW kW %    
31500   6.3,6.6
10.5,11,21
36,37
38.5
  30 128 0.57   12-14  
40000     36 149 0.57    
50000     43 179 0.53    
63000     50 209 0.53    
90000     64 273 0.45    
120000 220±8*1.25% 10.5,11,21
36,37
38.5
YNd11 79 338 0.45    
150000 230±8*2.5%   92 400 0.41    
180000     108 459 0.38    
120000     81 337 0.45    
150000   66
69
  96 394 0.41    
180000     112 451 0.38    
240000     140 560 0.30    

 

31500kVA-240000kVA three-phase three-flexing on-onus ICTUS mutabilis potentia TRANSFIGURATOR  
Ratum
capacitas
(kVA)
Voltage Compositum Nullus onus Damnum Load Loss Non Load
Current
Vector group Brevis circuitus
Impedimentum
%
capacitas
adsignatio
HV
(kV)
Med-ium Voltage
(kV)
LV
k(V)
kW kW %
31500     6.3
6.6
10.5
11
21
33
36
37
38.5
35 153.00 0.63   HM
12-14
HL
22-24
ML
7-9
100/100/100
100/50/100
100/100/50
40000     41 183.00 0.60  
50000     48 216.00 0.60  
63000   69 56 257.00 0.55  
90000 220±8*1.25% 115 10.5
11
21
33
36
37
38.5
73 333.00 0.44 YNyn0d11
120000 230±8*1.25% 121 92 410 0.44  
150000     108 487 0.39  
180000     124 598 0.39  
240000     154 741 0.35  

Nota 1The notitiae in tabula inscriptae applicandae sunt ad productorum structurarum depressurizatorum, et productorum structurarum boost etiam exigente provideri possunt.
Nota 2 Transformatores submissa intentione 35 kV etiam ut postulabat praeberi possunt.
Nota 3 Cum mediocris annui oneris commutator est inter 45% et 50%, maximum efficientiae operativae obtineri potest utendo valorem iacturae in mensa.

 

31500kVA-240000kVA three-phase three-flexer on-onus auto-iuncta potestas TRANSFIGURATOR  
Ratum
capacitas
(kVA)
Voltage Compositum Nullus onus Damnum Load Loss Non Load
Current
Vector group Brevis circuitus
Impedimentum
%
capacitas
adsignatio
HV
(kV)
Med-ium Voltage
(kV)
LV
(kV)
kW kW %
31500     6.3
6.6
10.5
21
36
37
38.5
20.0 102 0.44 YNyn0d11 HM
8-11
HL
28-34
ML
18-24
100/100/50
40000     24.0 125 0.44
50000     28.0 149 0.39
63000     33.0 179 0.39
90000 220±8*1.25% 115 40.0 234 0.33
120000 230±8*1.25% 121 10.5
21
36
37
38.5
51.0 292 0.33
150000     60.0 346 0.28
180000     68.0 398 0.28
240000     83.0 513 0.24

Nota 1 Notitia quae in tabula inscripta sunt, producta structurarum depressurizatorum applicanda sunt, et productorum structurarum boost etiam exigente provideri possunt.
Nota 2 Transformatores cum intentione humili 35 kV etiam ut requiritur provideri possunt.
Nota 3 Cum mediocris annui oneris commutator est inter 45% et 50%, maximum efficientiae operativae obtineri potest utendo valorem iacturae in mensa.

 

31500kVA-240000kVA three-phase three-flexer on-onus auto-iuncta potestas TRANSFIGURATOR
Ratum
capacitas
(kVA)
Voltage Compositum Nullus onus Damnum Load Loss Non Load
Current
Vector group Brevis circuitus
Impedimentum
%
capacitas
adsignatio
HV
(kV)
Med-ium Voltage
(kV)
LV
(kV)
kW kW %
31500     6.3
6.6
10.5
21
36
37
38.5
20.0 102 0.44 YNyn0d11 HM
8-11
HL
28-34
ML
18-24
100/100/50
40000     24.0 125 0.44
50000     28.0 149 0.39
63000     33.0 179 0.39
90000 220±8*1.25% 115 40.0 234 0.33
120000 230±8*1.25% 121 10.5
21
36
37
38.5
51.0 292 0.33
150000     60.0 346 0.28
180000     68.0 398 0.28
240000     83.0 513 0.24

1.Products exclusive in indice producti etiam in usuario requisita praeberi possunt. Performance productorum amet.
2. Medium voltage fabrica potest eligere valorem voltage aut sonum praeter ea quae in mensa super usoris exigentia nominantur. Summus intentione percussus eligere potest percussionem asymmetricam regulantem.
3. Brevis impedimentum ambitus alium pretii eligere potest quam ea quae in tabula definita sunt.
4.Final size is based on drawings of signed contract.

3


  • Previous:
  • Deinde: